Bộ 2 Lập Trình Pickit 3 Pickit 2 3.5
₫ 331.200
Sản phẩm Bộ 2 Lập Trình Pickit 3 Pickit 2 3.5 đang được mở bán với mức giá siêu tốt khi mua online, giao hàng online trên toàn quốc với chi phí tiết kiệm nhất,0 đã được bán ra kể từ lúc chào bán lần cuối cùng.Trên đây là số liệu về sản phẩm chúng tôi thống kê và gửi đến bạn, hi vọng với những gợi ý ở trên giúp bạn mua sắm tốt hơn tại Pricespy Việt Nam
Upgrade strengths:
- offline burn never dies.
Perfect support for all versions of software mplab、 mplab x
Never die offline, the sintering speed is faster.
2、 kit 3.5 never drop firmware.
Self-recovery of firmware, no shells are removed, no brush program
1 minute automatic recovery of firmware.
- strengthening interface protection.
Adopt 1812 self-restore fuse and powerful protection circuit.
- each kit 3 has a unique serial number.
Support mplab x to operate multiple kit 3.
- program voltage stability, the electricity supply is large.
- perfect interface protection circuits. Short circuits won 't be bad.
Pickit3 for development and use, also suitable for mass production and sintering. No computer can burn the program
Upgrade i: Import usb interface, eliminate the situation of usb interface loosening after multiple pullups.
Upgrade ii: New imitation transparent shell, use of quality materials, good toughness, durable.
Upgrade iii: At the request of customers, grinding noodles are used on the surface of the shell, reduced use of fingerprints、 scratches. More durable. (The original surface is light, it 's been a few days with fingerprint scratches)。
Pickit 3 main functional features:
- download speed fast. Usb connection is stable than icd 2/kit 2.
- offline sintering function. Develop debugging programming to use, do product mass offline sintering also makes.
- electricity supply output, internal voltage can be controlled directly by mplab ide software.
4、 pikcit 3, supports win 7 system. Icd2/kit2 64 win7
- high imitation of original shells (See photos), ultrascale volume: 95x39 x 11mm
- full-label design, full automatic patching processing, product quality is more stable and reliable.
Users use pickit 3 debugging, automatic upgrade, support the future micro-core company production of a new single chip machine. It is recommended to use mplab ide version 8.56 above software.
Standard configuration description:
1、 kit3 + Mainframe 1
- usb 1
3、 iscp 1
4、 6p 2 (Installed on the icsp line)
Pickit 3 comparison with other products
1、 comparison of pickit 3 with icd 2
1) 16 bit chips, download/debugging is much faster than icd 2. 16 bit chip simulation debugging must select kit 3.
2) Prices are far below icd 2, and there are as many pirates as cd 2, follow-up will exceed icd 2. Kit 3 already has 32 bit chips.
3) Connectivity is more reliable than icd2, icd 2 usb connections will not occur frequently, fixtures, this is the most headache of icd 2. Kit3, pull out, mplab ide software has tips, no firmware.
4) Official open standard circuits.
5) Support offline download, it can be suitable for field program upgrades and bulk programming.
6) Direct debugging pic 18 fxxk series, and pic 16 f72x vpp less than 10v, need not manually increase pressure relief circuit for vpp. Icd 2 does not have this function.
7) Sinter debugging power output, and you can adjust the software. E.g. Dspic33f, 3.3v can be supplied directly. (Icd2 does not have this
- offline burn never dies.
Perfect support for all versions of software mplab、 mplab x
Never die offline, the sintering speed is faster.
2、 kit 3.5 never drop firmware.
Self-recovery of firmware, no shells are removed, no brush program
1 minute automatic recovery of firmware.
- strengthening interface protection.
Adopt 1812 self-restore fuse and powerful protection circuit.
- each kit 3 has a unique serial number.
Support mplab x to operate multiple kit 3.
- program voltage stability, the electricity supply is large.
- perfect interface protection circuits. Short circuits won 't be bad.
Pickit3 for development and use, also suitable for mass production and sintering. No computer can burn the program
Upgrade i: Import usb interface, eliminate the situation of usb interface loosening after multiple pullups.
Upgrade ii: New imitation transparent shell, use of quality materials, good toughness, durable.
Upgrade iii: At the request of customers, grinding noodles are used on the surface of the shell, reduced use of fingerprints、 scratches. More durable. (The original surface is light, it 's been a few days with fingerprint scratches)。
Pickit 3 main functional features:
- download speed fast. Usb connection is stable than icd 2/kit 2.
- offline sintering function. Develop debugging programming to use, do product mass offline sintering also makes.
- electricity supply output, internal voltage can be controlled directly by mplab ide software.
4、 pikcit 3, supports win 7 system. Icd2/kit2 64 win7
- high imitation of original shells (See photos), ultrascale volume: 95x39 x 11mm
- full-label design, full automatic patching processing, product quality is more stable and reliable.
Users use pickit 3 debugging, automatic upgrade, support the future micro-core company production of a new single chip machine. It is recommended to use mplab ide version 8.56 above software.
Standard configuration description:
1、 kit3 + Mainframe 1
- usb 1
3、 iscp 1
4、 6p 2 (Installed on the icsp line)
Pickit 3 comparison with other products
1、 comparison of pickit 3 with icd 2
1) 16 bit chips, download/debugging is much faster than icd 2. 16 bit chip simulation debugging must select kit 3.
2) Prices are far below icd 2, and there are as many pirates as cd 2, follow-up will exceed icd 2. Kit 3 already has 32 bit chips.
3) Connectivity is more reliable than icd2, icd 2 usb connections will not occur frequently, fixtures, this is the most headache of icd 2. Kit3, pull out, mplab ide software has tips, no firmware.
4) Official open standard circuits.
5) Support offline download, it can be suitable for field program upgrades and bulk programming.
6) Direct debugging pic 18 fxxk series, and pic 16 f72x vpp less than 10v, need not manually increase pressure relief circuit for vpp. Icd 2 does not have this function.
7) Sinter debugging power output, and you can adjust the software. E.g. Dspic33f, 3.3v can be supplied directly. (Icd2 does not have this